Specifications
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Broan Hartford, Wisconsin www.broan.com 800-558-1711
Venmar Ventilation ULC Drummondville (Quebec), Canada www.broan.ca 877-896-1119
SPECIFICATION SHEET
91D 1100249D
MODEL AE50110DCS
FLEX DC
TM
SERIES
HUMIDITY SENSING FAN
A modern-styled, high performance fan, with sensing
circuitry, that "knows" when to ventilate the room.
FEATURES
BLOWER:
• Plug-in, permanently lubricated, brushless DC motor -
engineered for continuous operation
• Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
• Low RPM for quiet operation
• Selectable settings of 50, 80 or 110 CFM
HOUSING:
• Rugged, 26 gauge, galvanized steel construction
• Polymeric, 4” damper / duct connector with tapered sleeve
and no metallic clatter
• 5-3/4” height allows for 2” x 6” ceiling installations
• Sturdy, easy, four-point mounting directly to joist
• Optional snap-on flange kit
GRILLE:
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
AUTOMATIC CONTROL:
• Humidity control automatically turns fan ON when either of
these conditions is detected:
- a rapid to moderate (user adjustable) increase of humidity
- humidity above user-adjustable set-point (50%-80% RH)
• Two wire manual operation for odor control - Turns fan ON
when power line through wall switch is cycled ON, OFF
and back ON
• Remains ON for a user-adjustable 5 to 60 minutes after
humidity has stabilized and is below set-point or after
manually initiated through power line cycling
• Saves energy because unit runs only for the time required.
A unit controlled with a wall timer may keep fan ON longer
than required or turn it OFF before room is sufficiently
ventilated
TYPICAL SPECIFICATION
Fan shall be Broan Model AE50110DCS.
Fan shall have corrosion resistant galvanized steel housing
with four-point mounting capability. It shall be ducted to a
roof or wall cap using 4” round ductwork.
Blower assembly shall be removable, have a centrifugal
blower wheel and a permanently lubricated brushless DC
motor designed for continuous operation.
Non-metallic damper/duct connector shall be included.
Air delivery shall be no less than the airflow values and
no greater than the sound level values listed in the HVI
Performance Ratings provided in this specification (see
following chart). All air and sound ratings shall be certified
by HVI.
Fan shall be acceptable for use in insulated ceilings (Type
I.C.) and cULus Listed for use over bathtubs and showers
when connected to a GFCI protected branch circuit.
cULus Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit (ceiling mount
only)
Acceptable for use in insulated ceilings (Type I.C.)
3-Year Warranty