Operating Manual for MUX22 BroaMan device with Optocore® and SANE® integration © Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr. 8 82166 Munich-Gräfelfing Germany BroaMan MUX22 Operating Manual Rev. 2.
Page intentionally left blank.
Important Safety Instructions • Please read this operating manual carefully. • Please keep this operating manual in a safe place. • Heed all warnings. • Follow all instructions. • This device may only be used in accordance to the information provided in this operating manual. Ensure that all recommendations, especially the safety recommendations as detailed in this operating manual, are followed before and during the usage of the device.
Owner Information • Operating Manual Please read this manual. If you call for technical support, we will assume that you have already done so. Study the operating manual carefully in order to familiarise yourself with the device and its operation. The operating manual contains important information on proper use of the device. It cannot be guaranteed that this operating manual will not contain typographical mistakes or misprints. The operating manual is regularly revised and updated.
• Water and Moisture etc. To prevent fire or shock hazard do not expose the device to direct sunlight, dust, water or rain during operation or storage. • Cleaning Only use a dry linen cloth to clean the device. If the unit is very dirty, moisten a cloth using a little water and a small amount of household detergent. Never use cleansing agents containing solvents to clean the device.
• External objects and/or liquids with the device Never push objects of any kind into the device through openings in the casing. They may come into contact with dangerous voltage points or short out parts that could result in fire or electric shock. Never spill liquid of any kind on the device. • Cables and Accessories Only use attachments that are specified by the manufacturer of the device. Use high quality, properly terminated, cables to connect the device.
CE/FCC Conformity This document confirms that the product MUX22 bearing the CE (Communauté Européenne) label meets all requirements in the EMC directive 2004/108/EG laid down by the Member States Council for adjustment of legal requirements. Furthermore the product complies with the rules and regulations of the low-voltage directive 2006/95/EG and the Restriction of Hazardous Substances Recast Directive 2011/65/EU (RoHS 2).
Page intentionally left blank.
BroaMan MUX22 Table of Contents Important Safety Instructions..................................................................................................................................... 3 Owner Information ..................................................................................................................................................... 4 CE/FCC Conformity........................................................................................................................
Auxiliary Ports – RS485/GPIO/RS422 .........................................................................................................29 RS232 Connection .......................................................................................................................................29 Connector Hood Quality ...............................................................................................................................29 USB Connection ..................................
Device Description Congratulations on your purchase of a MUX22 - 3G/HD/SD-SDI electrical-optical converter with integrated Wavelength Division Multiplexer (CWDM/DWDM) and interface to Optocore® and SANE® for joint transport of video, audio and data over a duplex fiber connection. This manual will quickly demonstrate the advantages of the device and help ease your day-to-day workload in the professional audio-visual environment.
Front Panel MUX22 IVT/IC444; IVT/IC422; IVT/IC485; IVT/ICAES Word Clock LED: Indicates the selected Sync/Word Clock source: INT: BNC: NET: Internal Sync/Word Clock of the device External via the BNC SYNC input Sync/Word Clock received from the Optocore network Signal Monitor LED for 4 Duplex Audio Channels: IC422: IC485: IC444: ICAES: Four-wire intercom ports with bi-directional RS422 (for Clear-Com) Four-wire intercom ports with bi-directional RS485 (for RTS) Line Level I/O with GPIO Bi-directional A
HEALTH LED: PWR 1 LED: PWR 2 LED: Green: Power supply to the device is working; temperature is within limits Green: Power supply 1 is receiving power and working Green: Power supply 2 is receiving power and working USB connector: USB LED: USB connection for remote control via PC Green: Indicates data activity RS232 connector: RS232 (D-Sub-9) connection for remote control and firmware updates via PC LAN LINK LED: S1: S2: UP: L1: L2: Ethernet communication is established via SANE 1 (rear panel) Etherne
MUX22 IVT/MADI-OPT; IVT/MADI-BNC Word Clock LED: Indicates the selected Sync/Word Clock source: INT: BNC: NET: Internal Sync/Word Clock of the device External via the BNC SYNC input Sync/Word Clock received from the Optocore network Signal Monitor LED for 4 Duplex MADI: BNC: FO: CAT: POE: Four Dual Coaxial MADI Four Bi-Directional Optical SC MADI Future option Future option ERROR: LAN: MADI: POWER: Red: Error with incoming MADI signal Yellow: Ethernet communication present Green: MADI Signal present
USB connector: USB LED: USB connection for remote control via PC Green: Indicates data activity RS232 connector: RS232 (D-Sub-9) connection for remote control and firmware updates via PC LAN LINK LED: S1: S2: UP: L1: L2: Ethernet communication is established via SANE 1 (rear panel) Ethernet communication is established via SANE 2 (rear panel) There is another device with an enabled Ethernet port on the network Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is establ
MUX22 IVT Word Clock LED: Indicates the selected Sync/Word Clock source: INT: BNC: NET: Internal Sync/Word Clock of the device External via the BNC SYNC input Sync/Word Clock received from the Optocore network Signal Monitor LED for 8 3G/HD/SDI Channels: IVT: MR: R33: VSP: Intelligent Video Tunnel currently not used currently not used currently not used PEAK: LEVEL: SIGNAL: MUTE: Red: Optical power exceeds the maximum input level of the receiver Yellow: Optical power is in proper range and good cond
LAN LINK LED: S1: S2: UP: L1: L2: Ethernet communication is established via SANE 1 (rear panel) Ethernet communication is established via SANE 2 (rear panel) There is another device with an enabled Ethernet port on the network Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is established via LAN 2 (rear panel) Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz BroaMan MUX22 Operating Manual Rev. 2.
MUX22 IVT/IVT Word Clock LED: Indicates the selected Sync/Word Clock source: INT: BNC: NET: Internal Sync/Word Clock of the device External via the BNC SYNC input Sync/Word Clock received from the Optocore network Signal Monitor LED for 16 3G/HD/SDI Channels: IVT: MR: R33: VSP: Intelligent Video Tunnel currently not used currently not used currently not used PEAK: LEVEL: SIGNAL: MUTE: Red: Optical power exceeds the maximum input level of the receiver Yellow: Optical power is in proper range and good
S2: UP: L1: L2: Ethernet communication is established via SANE 2 (rear panel) There is another device with an enabled Ethernet port on the network Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is established via LAN 2 (rear panel) Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz BroaMan MUX22 Operating Manual Rev. 2.
Rear Panel MUX22 IVT/IC422; IVT/IC485; IVT/ICAES RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
MUX22 IVT/IC444 RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
MUX22 IVT/MADI-OPT MUX22 IVT/MADI-BNC RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
SANE 1: SANE 2: SANE RJ-45 interface for audio transmission and 100 Mbit Ethernet SANE RJ-45 interface for audio transmission and 100 Mbit Ethernet LINK 1: Full-duplex, full bandwidth LC-type optical interface for Optocore transmission (SFP transceiver – type depending on a specyfication) LINK 2: Full-duplex, full bandwidth LC-type optical interface for Optocore transmission (SFP transceiver – type depending on a specyfication) LAN 1: LAN 2: 100 Mbit RJ-45 Ethernet interface 100 Mbit RJ-45 Ethernet i
MUX22 IVT MUX22 IVT/IVT RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
SANE 1: SANE 2: SANE RJ-45 interface for audio transmission and 100 Mbit Ethernet SANE RJ-45 interface for audio transmission and 100 Mbit Ethernet LINK 1: Full-duplex, full bandwidth LC-type optical interface for Optocore transmission (SFP transceiver – type depending on a specyfication) LINK 2: Full-duplex, full bandwidth LC-type optical interface for Optocore transmission (SFP transceiver – type depending on a specyfication) LAN 1: LAN 2: 100 Mbit RJ-45 Ethernet interface 100 Mbit RJ-45 Ethernet i
Device Details BNC-SDI Ports MUX22 can be factory fitted with 0-4 (in a special version up to 8) dual-channel video ports, which are specified at the time of ordering. Each port can be equipped with a high quality BNC connector, providing 3G/HD/SD-SDI connectivity.
synchronise to the same system clock. IC444 - Line Level I/O and GPIO The IC444 module is populated with one 37-pin male and one 37 pin female D-Sub connector. The female connector has 4 line level inputs and 4 optically isolated General Purpose Inputs (GPI). The male connector has 4 line level outputs 4 General Purpose Outputs (GPO) with relay. Auxiliary +12V DC and +5V DC power is available on both connectors, allowing up to 100mA of current to be drawn from each IC444 module.
Sync MUX22 is equipped with a Sync board enabling software configurable Word Clock or Bi-/Tri-Level Sync inputs and outputs. Any device on the network can act as master of the network and distribute any type of Word Clock/Bi-Tri-Level Sync signal to networked BroaMan, Optocore or SANE devices. The user can decide whether to lock the BroaMan device and system to the external source or to the internal sync generated in the device.
Connectors and Cables SD/HD/3G-SDI Ports Use 75 Ω coaxial cable with BNC connectors. The cable and connectors used should comply with the digital SD/HD/3G-SDI transmission standards. The maximum cable length is dependent on the bandwidth of the signal (SD, HD or 3G) and the specifications and quality of the cable and connectors. Optical Connections Each MUX22 features internal and external fiber connections.
USB Connection Use USB-A to USB-B cable between the PC and the device. LAN Connection Use a standard twisted pair cable (Cat-5, Cat-6) with RJ-45 connectors. Word Clock/Sync Connection Use 75 Ω coaxial cable with BNC connectors. Power Connection Use power cords with IEC C13 connectors. Ordering Options Below tables list the configurations available as a standard devices with unique ordering code. Please refer to the specific code when ordering.
MUX22 IVT/IC485 Code M224445R515002PA1 Description Mux22-IVT/IC485 M224445GP15002PA1 4 x 3G-SDI IN, 4 x 3G-SDI OUT, 4 x RTS 4-wire Intercom, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/LAN/MADI Cat5, 2 x LAN, 4 x RS485/422, 2 PSU, 1 x 1310nm Aux Mux22-IVT/IC485 M226245R515002PA1 4 x 3G-SDI IN, 4 x 3G-SDI OUT, 4 x RTS 4-wire Intercom, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/LAN/MADI Cat5, 2 x LAN, 4 x GPIO, 2 PSU, 1 x 1310nm Aux Mux22-IVT/IC485 M226245GP15002PA1 6 x 3G-SDI IN, 2 x 3G-SDI OUT, 4 x RT
M228044GP15002PA1 Mux22-IVT/IC444 M220844R515002PA1 8 x 3G-SDI IN, 4 x Line In, 4 x Line Out, 4 x GPIO, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/LAN/MADI Cat5, 2 x LAN, 4 x GPIO, 2 PSU, 1 x 1310nm Aux Mux22-IVT/IC485 M220844GP15002PA1 8 x 3G-SDI OUT, 4 x Line In, 4 x Line Out, 4 x GPIO, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/LAN/MADI Cat5, 2 x LAN, 4 x RS485/422, 2 PSU, 1 x 1310nm Aux Mux22-IVT/IC485 8 x 3G-SDI OUT, 4 x Line In, 4 x Line Out, 4 x GPIO, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/L
M2226MOR515002PA1 Mux22-IVT/MADI-OPT M2226MOGP15002PA1 2 x 3G-SDI IN, 6 x 3G-SDI OUT, 4 x duplex fiber MADI, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/LAN/MADI Cat5, 2 x LAN, 4 x RS485/422, 2 PSU, 1 x 1310nm Aux Mux22-IVT/MADI-OPT M2280MOR515002PA1 2 x 3G-SDI IN, 6 x 3G-SDI OUT, 4 x duplex fiber MADI, 2 x PSU, 1 x SM Optocore Link, 2 x nd SANE/LAN/MADI Cat5, 2 x LAN, 4 x GPIO, 2 PSU, 1 x 1310nm Aux Mux22-IVT/MADI-OPT M2280MOGP15002PA1 8 x 3G-SDI IN, 4 x duplex fiber MADI, 2 x PSU, 1 x SM Optocore Li
Connector Pin Out Pin-out Four-Wire Intercom port - TO PANEL – ClearCom (IC422) Channel Pin Audio In Audio Out RS422 In RS422 Out + 3 4 1 7 - 6 5 2 8 Use this pin-out only for devices loaded with ClearCom modules (IC422) RJ-45 Pin-out Four-Wire Intercom port - TO MATRIX – ClearCom (IC422) Channel Pin Audio In Audio Out RS422 In RS422 Out + 4 3 7 1 - 5 6 8 2 Use this pin-out only for devices loaded with ClearCom modules (IC422) RJ-45 Pin-out Four-Wire Intercom port - TO P
Pin-out Four-Wire AES port - TO PANEL – AES based intercom systems (ICAES) Channel Pin TX RX + 3 1 - 6 2 Use this pin-out only for devices loaded with AES modules (ICAES) RJ-45 Pin-out Four-Wire AES port – TO MATRIX – AES based intercom systems (ICAES) Channel TX RX + 1 3 - 2 6 Pin Use this pin-out only for devices loaded with AES modules (ICAES) RJ-45 Pin-out Line Level Inputs / General Purpose Inputs (IC444) Line Level Input General Purpose Input 1 2 3 4 + 21 23 25 27
Pin-out Auxiliary Port - 4 x RS485 Pin Please verify the correct polarity of adaptors. RS485 Channel 1 2 3 4 + 1 2 3 4 - 6 7 8 9 GND Software configurable for duplex (RS485) or simplex (RS422) operation. 5 An adaptor must be constructed for connectivity to MIDI or CAN interfaces. D-Sub-9- female Locking system acc. to 4-40 UNC Pin-out Auxiliary Port - 4 x GPIO GPI Channel Pin Electro Isolated.
Pin-out Optical Fiber-Port Optocore Pin SDI* MADI TXD RXD TXD RXD TXD RXD 2 1 2 1 2 1 * Assumes standard Input / Output transceiver. Non-standard Input / Input and Output / Output transceivers for SDI video I/O are available LC and SC connectors Pin-out RS232 - Port RS232 Channel Pin RXD TXD 3 2 Internally bridged 1, 4, 6 7, 8 D-Sub-9- female Power +5VS GND 9 5 Use standard RS232 cable, male – female, to connect to PC Locking system acc.
Connection Examples GPI/GPO IC444 Module BroaMan MUX22 Operating Manual Rev. 2.
Technical Specifications Video Standards Complies with SMPTE Interface SD, ED, HD, Dual Link, 3G 259M, 292M, 344M, 372M, 424M SDI – Serial Digital Interface Optical Connection Complies with 21 CFR 1040.10 and 1040.11 SANE, LAN Convention TIA - 568A/B, Optocore TIA - 568A/B, IEEE - 802.3 200 Mbit/s 10/100 Mbit/s Hardware standard BNC - 75 Ω Depending on selected sample rate Output Input Output Referring to GND Input Up to 192 kHz ≤5Ω 75 Ω ≥ 1 Vpp + 1.7 V ≥ 400 mVpp Convention EIA / TIA - 232 USB 2.
Dimensions and Weight Dimensions Front panel: width height depth 483 mm / 19 inch 44 mm / 1.73 inch 200 mm / 7.87 inch Rear panel: width 438 mm / 17.25 inch Weight Dependent on the configuration of each specific device. Not more then 3kg. Please note: Modifications that serve the purpose of technical improvement may be carried out without prior notification. BroaMan MUX22 Operating Manual Rev. 2.
Warranty and Liability Summary of Warranty Broaman Mux22 device is warranted against defects in material and workmanship for 60 months (5 years) from the date of purchase. This warranty does not include mechanical damages caused by misuse. This warranty covers the original registered purchaser only and is not transferable. This warranty does not apply to devices which have been purchased in used condition or demonstrator equipment.
Package Contents MUX22 is a part of the ordered system. Each MUX22 package should consist of: • 1 MUX22 unit • 1 LC-LC 0.25m fibre patch cable • 2 power cables Any additionally purchased equipment such as optical fiber cables in required lengths, D-Sub cables and adapters, RS232 cables, and international electric cables, which have been supplied on your request and your purchase order, cannot be listed above.
Company Information Mailing Address: BROAMAN GmbH Lohenstr. 8 D-82166 Munich-Gräfelfing Germany Telephone: +49 – (0)89 – 89996460 Facsimile: +49 – (0)89 – 89996479 Internet: www.BroaMan.com Email: inquiry@broaman.com BroaMan MUX22 Operating Manual Rev. 2.