36
Pin-out
Auxiliary Port - 4 x RS485
Channel
RS485
GND
Please verify the correct polarity of adaptors.
Software configurable for duplex (RS485) or
simplex (RS422) operation.
An adaptor must be constructed for connectivity
to MIDI or CAN interfaces.
1
2
3
4
Pin
+
1
2
3
4
5
-
6
7
8
9
D-Sub-9- female
Locking system acc. to 4-40 UNC
Pin-out
Auxiliary Port - 4 x GPIO
Channel
GPI
GPO
GND
Electro Isolated.
Available as a
factory fitted
replacement
option for the
serial ports.
1
2
3
4
1
2
3
4
Pin
+
3
6
10
13
1
4
11
14
7, 8, 9
-
GND
GND
GND
GND
2
5
12
15
HD-Sub-15- female
Locking system acc. to 4-40 UNC
Pin-out
Auxilary Port 4 x Dual RS422
RS422 Input (RX)
RS422 Output (TX)
GND
Software
configurable for
duplex (RS485)
operation.
Available as a
factory fitted
replacement
option for the
serial ports.
1
2
3
4
1
2
3
4
10, 11,
12, 13,
14, 15,
16, 17,
18
Pin
+
1
3
5
7
19
21
23
25
-
2
4
6
8
20
22
24
26
HD-SUB-26 female
Pin-out
SANE Synchronous Audio and Ethernet
SANE /
MADI RX
SANE /
MADI TX
Ethernet
RX
Ethernet
TX
A device compatible with
10/100MB Fast Ethernet can be
connected to a SANE port for
Ethernet data communication.
Pin
+
7
4
3
1
-
8
5
6
2
RJ-45