Datasheet

3
Device Selection Guide
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
Color and Dominant
Wavelength
(nm), Typ.
[3]
Lamps without
Standos on Leads
(Outline Drawing A)
Lamps with Standos
on Leads
(Outline Drawing B)
Luminous Intensity
Iv (mcd)
[1,2,5]
@ 20 mA
Min. Max.
15° Amber 590 HLMP-EL15-PS000 880 2500
HLMP-EL15-QSK00 1150 2500
HLMP-EL15-QT000 1150 3200
HLMP-EL15-UX000 HLMP-EL17-UX000 3200 9300
HLMP-EL15-VY000 HLMP-EL17-VY000 4200 12000
HLMP-EL15-VYK00 4200 12000
HLMP-EL15-VW000 4200 7200
Orange 605 HLMP-EJ17-QT000 1150 3200
HLMP-EJ15-PS000 880 2500
HLMP-EJ15-RU000 1500 4200
HLMP-EJ15-SV000 HLMP-EJ17-SV000 1900 5500
Red-Orange 615 HLMP-EH15-QT000 1150 3200
HLMP-EH15-RU000 1500 4200
HLMP-EH15-TW000 2500 7200
Red 626 HLMP-EG15-PS000 880 2500
HLMP-EG15-QT000 1150 3200
HLMP-EG15-RU000 HLMP-EG17-RU000 1500 4200
HLMP-EG15-UX000 HLMP-EG17-UX000 3200 9300
HLMP-EG15-TW000 HLMP-EG17-TW000 2500 7200
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ
1/2
is the o-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.