Datasheet

8
Figure 5. Spatial radiation pattern – 35 x 70 degree lamps.
Vf Bin Table
[2,3]
Bin Id Min. Max.
VA 2.0 2.2
VB 2.2 2.4
VC 2.4 2.6
Notes:
1. All bin categories are established for classication of products.
Products may not be available in all bin categories. Please contact
your Avago representative for further information.
2. Vf bin table only available for those numbers with options -xxRxx,
-xxSxx, -xxTxx.
3. Tolerance for each bin limit is ± 0.05V
HLMP-ALXX fig 8a
RELATIVE INTENSITY – %
100
0
VERTICAL ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
50
10
30
40
40 020 -10 -30 -50
90
30 10 -20 -40
HLMP-ALXX fig 8b
RELATIVE INTENSITY – %
100
0
HORIZONTAL ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
50
10
30
40
40 020 -10 -30 -50
90
30 10 -20 -40
Intensity Bin Limits (mcd at 20 mA)
Bin Name Min. Max.
K 310 400
L 400 520
M 520 680
N 680 880
P 880 1150
Q 1150 1500
R 1500 1900
S 1900 2500
T 2500 3200
U 3200 4200
Tolerance for each bin limit is ±15%.
Amber Color Bin Limits (nm at 20 mA)
Bin Name Min. Max.
1 584.5 587.0
2 587.0 589.5
4 589.5 592.0
6 592.0 594.5
Tolerance for each bin limit is ± 0.5 nm.