Datasheet

8
Orange
Device
HLMP- Parameter Symbol Min. Typ. Max. Units Test Conditions
P402-F00xx 1.0 4.0
P405-F00xx 1.0 6
P405-JK000 Luminous Intensity I
V
4.0 12.5 mcd I
F
= 10 mA
Q400-F00xx 1.0 8
Q405-H00xx 2.5 14
All Forward Voltage V
F
1.5 1.9 3.0 V I
F
= 10 mA
Reverse Breakdown Voltage V
R
5.0 30.0 V I
R
= 100 µA
P40x Included Angle Between 2q
1
/
2
125 Deg.
Q40x
Half Intensity Points
[2]
90
Peak Wavelength l
PEAK
600 nm
Dominant Wavelength
[3]
l
d
602 nm Measured at Peak
Spectral Line Half Width Dl
1/2
40 nm
All Speed of Response t
s
260 ns
Capacitance C 4 pF V
F
= 0; f = 1 MHz
Thermal Resistance Rq
J-PIN
170 °C/W Junction-to-Cathode Lead
Luminous Ecacy
[4]
h
v
380 lm/W