Datasheet

5
10 10040 7020 60 8030 50 90
LUMINOUS FLUX TO INTENSITY RATIO
WITHIN A GIVEN CONE ANGLE
0
10
20
30
40
50
60
70
80
90
0
0.02
0.04
0.06
0.08
0.10
0.12
0.14
0.135
ϕ
N
(θ)
I
V
(0)
θ – ANGLE FROM OPTICAL CENTERLINE – DEGREES
(CONE HALF ANGLE)
NORMALIZED INTENSITY
0
Figure 7. Relative luminous intensity vs. angular displacement.
Intensity Bin Limits
Color Bin
Intensity Range (mcd)
Min. Max.
Red
P 540.0 850.0
Q 850.0 1200.0
R 1200.0 1700.0
S 1700.0 2400.0
T 2400.0 3400.0
U 3400.0 4900.0
V 4900.0 7100.0
W 7100.0 10200.0
X 10200.0 14800.0
Y 14800.0 21400.0
Z 21400.0 30900.0
Maximum tolerance for each bin limit is ±18%.
Mechanical Option Matrix
Mechanical Option Code Denition
00 Bulk Packaging, minimum increment 500 pcs/bag
Note:
All categories are established for classication of products. Products may not be available in all categories. Please contact your local Avago