Datasheet

3
Absolute Maximum Ratings at T
A
= 25°C
Parameter HLMP-R100 HLMP-0301 HLMP-0401 HLMP-0504 Units
Peak Forward Current 300 90 60 90 mA
Average Forward Current
[1]
20 25 20 25 mA
DC Current
[2]
30 30 20 30 mA
Power Dissipation 87 135 85 135 mW
Reverse Voltage (I
R
= 100 μA)
5 5 5 5 V
Transient Forward Current
[3]
(10 μs Pulse)
500 500 500 500 mA
Operating Temperature Range -20 to +100 -40 to +100 -40 to +100 -20 to +100 °C
Storage Temperature Range -40 to +100 -40 to +100 -40 to +100 -40 to +100
Notes:
1. See Figure 5 to establish pulsed operating conditions.
2. For AlGaAs Red, Red, and Green Series derate linearly from 50°C at 0.5 mA/°C. For Yellow Series derate linearly from 50°C at 0.2 mA/°C.
3. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED die and
wirebond. It is not recommended that the device be operated at peak current beyond the peak forward current listed in the Absolute Maximum
Ratings.