Datasheet

4
Plastic Optical Fiber Connector Mechanical/Optical Characteristics
T
A
= -40 to +85°C, Unless Otherwise Specified.
Parameter Part Number Symbol Min. Typ.
[1]
Max. Units Temp. °C Note
Retention Force, Simplex, F
R-C
78 N +25 2
Connector to HFBR-4501Z/4511Z 3 -40 to +85
Simplex Latching, 47 80 +25
HFBR-4503Z/4513Z 11 -40 to +85
Duplex, 7 12 +25
HFBR-4506Z 4 -40 to +85
Duplex Latching, 50 80 +25
HFBR-4516Z 15 -40 to +85
Tensile Force, Simplex, F
T
8.5 22 N 3
Connector to Cable HFBR-4501Z/4511Z
Simplex Latching, 8.5 22
HFBR-4503Z/4513Z
Duplex, HFBR-4506Z 14 35
Duplex Latching, 14 35
HFBR-4516Z
Adapter Connector HFBR-4505Z/4515Z with α
CC
0.7 1.5 2.8 dB 25 4, 5
to Connector Loss HFBR-4501Z/4511Z
Retention Force HFBR-4505Z/4515Z with F
R-B
78 N
Connector to Adapter HFBR-4501Z/4511Z
Insertion Force, Simplex, F
I
830N 6
HFBR-4501Z/4511Z
Simplex Latching, 16 35
HFBR-4503Z/4513Z
Duplex, HFBR-4506Z 13 46
Duplex Latching 22 51
HFBR-4516Z
Notes:
1. Typical data are at +25°C.
2. No perceivable reduction in retention force was observed after 2000 insertions. Retention force of non-latching connectors is lower at elevated
temperatures. Latching connectors are recommended for applications where a high retention force at high temperatures is desired.
3. For applications where frequent temperature cycling over temperature extremes is expected, please contact Avago Technologies for alternate
connectoring techniques.
4. Minimum and maximum limit for α
CC
for 0°C to +70°C temperature range. Typical value of α
CC
is at +25°C.
5. Factory polish or field polish per recommended procedure.
6. Destructive insertion force was typically at 178 N (40 lb.).
Versatile Link
Transmitters and
Receivers
Connector to Versatile
Link Transmitters and
Receivers
Plastic Optical Fiber Connector Absolute Maximum Ratings
Parameter Symbol Min. Max. Unit Note
Storage and Operating Temperature T
S,O
-40 85 °C1
Recommended Operating Temperature T
O
-40 85 °C1
Installation Temperature T
l
070 °C1
Nut Torque T
N
0.7 N-m 2
100 OzF-in.
Notes:
1. Storage and Operating Temperatures refer to the ranges over which the connectors can be used when not subjected to mechanical stress.
Installation Temperature refers to the ranges over which connectors may be installed onto the fiber and over which connectors can be connected
and disconnected from transmitter and receiver modules.
2. Recommended nut torque is 0.57 N-m.
HFBR-4505Z/4515Z Adapter