Datasheet
7
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
HCPL-772X HCPL-072X
Description Symbol Option 060 Option 060 Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms I-IV I-IV
for rated mains voltage ≤300 V rms I-IV I-III
for rated mains voltage ≤450 V rms I-III
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 560 V peak
Input to Output Test Voltage, Method b† V
PR
1181 1050 V peak
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a† V
PR
945 840 V peak
V
IORM
x 1.5 = V
PR
, Type and Sample Test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage† V
IOTM
6000 4000 V peak
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature T
S
175 150 °C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
10
= 500 V R
IO
≥10
9
≥10
9
Ω
† Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations
section IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
The surface mount classication is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Figure
Storage Temperature T
S
–55 125 °C
Ambient Operating Temperature
[1]
T
A
–40 +85 °C
Supply Voltages V
DD1
, V
DD2
0 6.0 Volts
Input Voltage V
I
–0.5 V
DD1
+0.5 Volts
Output Voltage V
O
–0.5 V
DD2
+0.5 Volts
Average Output Current I
O
10 mA
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Solder Reow Temperature Prole Section
Recommended Operating Conditions
Parameter Symbol Min. Max. Units Figure
Ambient Operating Temperature T
A
–40 +85 °C
Supply Voltages V
DD1
, V
DD2
4.5 5.5 V
Logic High Input Voltage V
IH
2.0 V
DD1
V 1, 2
Logic Low Input Voltage V
IL
0.0 0.8 V
Input Signal Rise and Fall Times t
r
, t
f
1.0 ms