Datasheet
6
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
HCPL-7710 HCPL-0710
Description Symbol Option 060 Option 060 Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms I-IV I-IV
for rated mains voltage ≤300 V rms I-IV I-III
for rated mains voltage ≤450 V rms I-III
Climatic Classication 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 560 V peak
Input to Output Test Voltage, Method b† V
PR
1181 1050 V peak
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a† V
PR
945 840 V peak
V
IORM
x 1.5 = V
PR
, Type and Sample Test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage† V
IOTM
6000 4000 V peak
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature T
S
175 150 °C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
10
= 500 V R
IO
≥10
9
≥10
9
Ω
†Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations sec-
tion IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classication is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units
Storage Temperature T
S
–55 125 °C
Ambient Operating Temperature T
A
–40 +100 °C
Supply Voltages V
DD1
, V
DD2
0 6.0 Volts
Input Voltage V
I
–0.5 V
DD1
+0.5 Volts
Output Voltage V
O
–0.5 V
DD2
+0.5 Volts
Input Current I
I
–10 +10 mA
Average Output Current I
O
10 mA
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Solder Reow Temperature Prole Section
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Ambient Operating Temperature T
A
–40 +100 °C
Supply Voltages V
DD1
, V
DD2
4.5 5.5 V
Logic High Input Voltage V
IH
2.0 V
DD1
V
Logic Low Input Voltage V
IL
0.0 0.8 V
Input Signal Rise and Fall Times t
r
, t
f
1.0 ms