IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description Symbol
HCPL-0454 HCPL-4504
HCPL-J454 HCNW4504 UnitOPTION 060 OPTION 060
Installation classication per
DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
I-IV
I-III
I-IV
I-IV
I-III
I-IV
I-IV
I-III
I-III
I-IV
I-IV
I-IV
I-IV
I-III
Climatic Classication 55/100/21 55/100/21 55/100/21 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2 2 2
Maximum Working Insulation Voltage V
IORM
560 630 891 1414 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec,
Partial Discharge < 5 pC
V
PR
1050 1181 1670 2652 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample
Test,
t
m
= 60 sec,
Partial Discharge < 5 pC
V
PR
840 945 1336 2121 V
peak
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values - Maximum
Values Allowed in the Event of a Failure,
also see Thermal Derating curve
V
IOTM
4000 6000 6000 8000 V
peak
Case Temperature T
S
150 175 175 150 °C
Input Current I
S,INPUT
150 230 400 400 mA
Output Power P
S,OUTPUT
600 600 600 700 mW
Insulation Resistance at T
S
,
V
IO
= 500 V
R
S
≥10
9
≥10
9
≥10
9
≥10
9
Ω
*Refer to the optocoupler section of the Designer's Catalog, under regulatory information (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test proles.
NOTE: These optocouplers are suitable for "safe electrical isolation" only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
NOTE: Insulation Characteristics are per IEC/EN/DIN EN 60747-5-2.
NOTE: Surface mount classication is Class A in accordance with CECC 00802.