Datasheet
6
Recommended Operating Conditions
Parameter Symbol Min. Max. Units Note
Power Supply V
CC
-V
EE
10 20 V
Input Current (ON) I
F(ON)
10 16 mA
Input Voltage (OFF) V
F(OFF)
-3.6 0.8 V
Operating Temperature T
A
-40 100 °C
Electrical Specications (DC)
Over recommended operating conditions unless otherwise specied.
Test
Parameter Symbol Min. Typ. Max. Units Conditions Fig. Note
High Level Output Current I
OH
0.5 A V
O
= V
CC
- 4 2, 3, 17 5
2.0 A V
O
= V
CC
-10 2, 3, 17 2
Low Level Output Current I
OL
0.5 A V
O
= V
EE
+2.5 5, 6, 18 5
2.0 A V
O
= V
EE
+10 5, 6, 18 2
High Level Output Voltage V
OH
V
CC
-4 V I
O
= -100 mA 1, 3, 19 6, 7
Low Level Output Voltage V
OL
0.5 V I
O
= 100 mA 4, 6, 20
High Level Supply Current I
CCH
3.0 6.0 mA Output Open 7, 8
I
F
= 10 to 16 mA
Low Level Supply Current I
CCL
3.0 6.0 mA Output Open 7, 8
V
F
= 3.0 to 0.8 mA
Threshold Input Current I
FLH
8.0 mA
Low to High I
O
= 0 mA, 9, 15, 21
Threshold Input Voltage V
FHL
0.8 V V
O
> 5 V
High to Low
Input Forward Voltage V
F
1.2 1.5 1.8 V I
F
= 10 mA 16
Temperature Coecient of DV
F
/DT
A
–1.6 mV/°C I
F
= 10 mA
Input Forward Voltage
UVLO Threshold V
UVLO+
7.9 V I
F
= 10 mA,
V
UVLO–
7.4 V V
O
> 5 V 22, 33
UVLO Hysteresis UVLO
HYST
0.5 V
Input Reverse Breakdown BV
R
5 V I
R
= 10 µA
Voltage
Input Capacitance C
IN
60 pF f = 1 MHz,
V
F
= 0 V