Datasheet
8
Electrical Specications (DC)
Over recommended operating conditions (T
A
= -40 to 100°C, I
F(ON)
= 7 to 16 mA, V
F(OFF)
= -3.6 to 0.8 V, V
CC
= 15 to 30 V,
V
EE
= Ground, each channel) unless otherwise specied.
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
High Level I
OH
0.1 0.4 A V
O
= (V
CC
- 4 V) 2, 3, 5
0.5 V
O
= (V
CC
- 15 V) 2
Low Level I
OL
0.1 0.6 A V
O
= (V
EE
+ 2.5 V) 5, 6, 5
0.5 V
O
= (V
EE
+ 15 V) 2
High Level Output V
OH
(V
CC
- 4) (V
CC
- 3) V I
O
= -100 mA 1, 3, 6, 7
Voltage 19
Low Level Output V
OL
0.4 1.0 V I
O
= 100 mA 4, 6,
Voltage 20
High Level I
CCH
2.5 5.0 mA Output Open, 7, 8 16
Supply Current I
F
= 7 to 16 mA
Low Level I
CCL
2.7 5.0 mA Output Open,
Supply Current V
F
= -3.0 to +0.8 V
Threshold Input I
FLH
2.2 5.0 mA HCPL-3150 I
O
= 0 mA, 9, 15,
Current Low to High 2.6 6.4 HCPL-315J V
O
> 5 V 21
Threshold Input V
FHL
0.8 V
Voltage High to Low
Input Forward Voltage V
F
1.2 1.5 1.8 V HCPL-3150 I
F
= 10 mA 16
1.6 1.95 HCPL-315J
Temperature ∆V
F
/∆T
A
-1.6 mV/°C I
F
= 10 mA
Coecient of
Forward Voltage
Input Reverse BV
R
5 V HCPL-3150 I
R
= 10 µA
Breakdown Voltage 3 HCPL-315J I
R
= 10 µA
Input Capacitance C
IN
70 pF f = 1 MHz, V
F
= 0 V
UVLO Threshold V
UVLO+
11.0 12.3 13.5 V V
O
> 5 V, 22,
V
UVLO-
9.5 10.7 12.0 I
F
= 10 mA 36
UVLO Hysteresis UVLO
HYS
1.6 V
*All typical values at T
A
= 25°C and V
CC
- V
EE
= 30 V, unless otherwise noted.
Output Current
17
18
Output Current