Datasheet
6
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description Symbol HCPL-3150#060 HCPL-315J Unit
Installation classication per DIN VDE
0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms I - IV
for rated mains voltage ≤ 300 Vrms I - IV I - IV
for rated mains voltage ≤ 600 Vrms I - III I - III
Climatic Classication 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 891 Vpeak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec, V
PR
1181 1670 Vpeak
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample
Test, t
m
= 60 sec, V
PR
945 1336 Vpeak
Partial discharge < 5 pC
Highest Allowable Overvoltage* V
IOTM
6000 6000 Vpeak
(Transient Overvoltage t
ini
= 10 sec)
Safety-Limiting Values – Maximum Values
Allowed in the Event of a Failure, Also
See Figure 37, Thermal Derating Curve.
Case Temperature T
S
175 175 °C
Input Current I
S, INPUT
230 400 mA
Output Power P
S, OUTPUT
600 1200 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥ 10
9
≥ 10
9
Ω
*Refer to the front of the optocoupler section of the current Catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description of Method a and Method b partial discharge test proles.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.