Insulation and Safety Related Specications
8-pin DIP Widebody
(300 Mil) SO-8 (400 Mil)
Parameter Symbol Value Value Value Unit Conditions
Minimum External L(101) 7.1 4.9 9.6 mm Measured from input terminals
Air Gap to output terminals, shortest
(External Clearance) distance through air.
Minimum External L(102) 7.4 4.8 10.0 mm Measured from input terminals
Tracking to output terminals, shortest
(External Creepage) distance path along body.
Minimum Internal 0.08 0.08 1.0 mm Through insulation distance,
Plastic Gap conductor to conductor, usually
(Internal Clearance) the direct distance between the
photoemitter and photodetector
inside the optocoupler cavity.
Minimum Internal NA NA 4.0 mm Measured from input terminals
Tracking to output terminals, along
(Internal Creepage) internal cavity.
Tracking Resistance CTI 200 200 200 V DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group IIIa IIIa IIIa Material Group
(DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classication is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-06xx Option 060 Only)
Description Symbol Characteristic Unit
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 V
rms
I-IV
for rated mains voltage ≤ 300 V
rms
I-IV
for rated mains voltage ≤ 600 V
rms
I-III
Climatic Classication 40/85/21
Pollution Degree (DIN VDE 0110/39) 2
Maximum Working Insulation Voltage V
IORM
567 V
peak
Input-to-Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec, V
PR
1063 V
peak
Partial Discharge < 5 pC
Input-to-Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
= 10 sec, V
PR
907 V
peak
Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 60 sec) V
IOTM
6000 V
peak
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature T
S
150 °C
Input Current** I
S,INPUT
150 mA
Output Power** P
S,OUTPUT
600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥10
9
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.