Datasheet
6
Insulation and Safety Related Specications
8-Pin DIP
(300 Mil) SO-8
Parameter Symbol Value Value Units Conditions
Minimum External Air L(101) 7.1 4.9 mm Measured from input terminals to
Gap (External output terminals, shortest distance
Clearance) through air.
Minimum External L(102) 7.4 4.8 mm Measured from input terminals to
Tracking (External output terminals, shortest distance
Creepage) path along body.
Minimum Internal Plastic 0.08 0.08 mm Through insulation distance, conductor
Gap (Internal Clearance) to conductor, usually the direct
distance between the photoemitter and
photodetector inside the optocoupler
cavity.
Tracking Resistance CTI 200 200 Volts DIN IEC 112/ VDE 0303 Part 1
(Comparative Tracking
Index)
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89,
Table 1)
Option 300 – surface mount classication is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description Symbol PDIP Option 060 SO-8 Option 60 Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms I-IV
for rated mains voltage ≤ 300 V rms I-IV I-III
for rated mains voltage ≤ 600 V rms I-III I-II
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 566 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test V
PR
1181 1063 V
peak
with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample Test, V
PR
945 849 V
peak
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage* V
IOTM
6000 4000 V
peak
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(See below for Thermal Derating Curve Figures)
Case Temperature T
S
175 150 ˚C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥ 10
9
≥ 10
9
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.