IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description Symbol PDIP Option 060 SO-8 Option 060 Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms I-IV
for rated mains voltage ≤ 300 V rms I-IV I-III
for rated mains voltage ≤ 600 V rms I-III I-II
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 560 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test V
PR
1181 1063 V
peak
with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample Test, V
PR
945 849 V
peak
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage* V
IOTM
6000 4000 V
peak
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(See below for Thermal Derating Curve Figures)
Case Temperature T
S
175 150 ˚C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥ 10
9
≥ 10
9
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
Thermal Derating Curve Figures
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – C
HCPL-060L/HCPL-063L
200
700
400
25
800
50 75 100
200
150 175
P
S
(mW)
I
S
(mA)
125
100
300
600
500
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – C
200
700
400
25
800
50 75 100
200
150 175
P
S
(mW)
I
S
(mA)
125
100
300
600
500
HCPL-260L/HCPL-263L