Datasheet

6
Insulation and Safety Related Specications
8-Pin DIP
(300 Mil) SO-8
Parameter Symbol Value Value Units Conditions
Minimum External Air L (101) 7.1 4.9 mm Measured from input terminals to output
Gap (External Clearance) terminals, shortest distance through air.
Minimum External Tracking L (102) 7.4 4.8 mm Measured from input terminals to output
(External Creepage) terminals, shortest distance path along body.
Minimum Internal Plastic 0.08 0.08 mm Through insulation distance, conductor
Gap (Internal Clearance) to conductor, usually the direct distance
between the photoemitter and
photodetector inside the optocoupler cavity.
Tracking Resistance CTI 200 200 Volts DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Regulatory Information
The HCPL-260L/060L/263L/063L have been approved by the following organizations:
UL
Approval under UL 1577, Component Recognition Program, File E55361.
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01
(Option 060 only)