Datasheet
5
Regulatory Information
The HCPL-2300 has been approved by the following or-
ganizations:
UL
Recognized under UL 1577, Component Recognition
Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01
(Option 060 only)
Solder Reow Temperature Prole
Recommended Pb-Free IR Prole
Insulation and Safety Related Specications
Parameter Symbol Value Units Conditions
Min. External Air Gap
(External Clearance)
L(IO1) 7.1 mm Measured from input terminals to output
terminals, shortest distance through air
Min. External Tracking Path
(External Creepage)
L(IO2) 7.4 mm Measured from input terminals to output
terminals, shortest distance path along body
Min. Internal Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity
Tracking Resistance
(Comparative Tracking Index)
CTI 200 Volts DIN IEC 112/VDE 0303 PART 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 – surface mount classication is Class A in accordance with CECC 00802.
Note: Non-halide ux should be used.
Note: Non-halide ux should be used.