Datasheet
11
Switching Specications (AC)
Over recommended operating conditions (T
A
= -40 to 100°C, for HCPL-3120,HCPL-J312 I
F(ON)
= 7 to 16mA, for
HCNW3120 I
F(ON)
= 10 to 16mA, V
F(OFF)
= -3.6 to 0.8 V, V
CC
= 15 to 30 V, V
EE
= Ground) unless otherwise specied.
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
Propagation Delay Time t
PLH
0.10 0.30 0.50 µs Rg = 10 Ω, 10, 11, 16
to High Output Level Cg = 10 nF, 12, 13,
Propagation Delay Time t
PHL
0.10 0.30 0.50 µs
f = 10 kHz, 14, 23
to Low Output Level
Duty Cycle = 50%
Pulse Width Distortion PWD 0.3 µs 17
Propagation Delay PDD -0.35 0.35 µs 35, 36 12
Dierence Between Any (t
PHL
- t
PLH
)
Two Parts
Rise Time t
r
0.1 µs 23
Fall Time t
f
0.1 µs
UVLO Turn On Delay t
UVLO ON
0.8 µs V
O
> 5 V, I
F
= 10 mA 22
UVLO Turn O Delay t
UVLO OFF
0.6 V
O
< 5 V, I
F
= 10 mA
Output High Level Common |CM
H
| 25 35 kV/µs T
A
= 25°C, 24 13, 14
Mode Transient Immunity I
F
= 10 to 16 mA,
V
CM
= 1500 V,
V
CC
= 30 V
Output Low Level Common |CM
L
| 25 35 kV/µs T
A
= 25°C, 13, 15
Mode Transient Immunity V
CM
= 1500 V,
V
F
= 0 V, V
CC
= 30 V
*All typical values at T
A
= 25°C and V
CC
- V
EE
= 30 V, unless otherwise noted.