Datasheet
10
Electrical Specications (DC)
Over recommended operating conditions (T
A
= -40 to 100°C, for HCPL-3120, HCPL-J312 I
F(ON)
= 7 to 16mA, for
HCNW3120 I
F(ON)
= 10 to 16mA, V
F(OFF)
= -3.6 to 0.8 V, V
CC
= 15 to 30 V, V
EE
= Ground) unless otherwise specied.
Parameter Symbol Device Min. Typ.* Max. Units Test Conditions Fig. Note
High Level Output I
OH
0.5 1.5 A V
O
= (V
CC
- 4 V) 2, 3, 5
Current
2.0 A V
O
= (V
CC
- 15 V)
17
2
Low Level Output I
OL
0.5 2.0 A V
O
= (V
EE
+ 2.5 V) 5, 6, 5
Current
2.0 A V
O
= (V
EE
+ 15 V)
18
2
High Level Output V
OH
(V
CC
- 4) (V
CC
- 3) V I
O
= -100 mA 1, 3, 6, 7
Voltage 19
Low Level Output V
OL
0.1 0.5 V I
O
= 100 mA 4, 6,
Voltage 20
High Level Supply I
CCH
2.5 5.0 mA Output Open, 7, 8
Current I
F
= 7 to 16 mA
Low Level Supply I
CCL
2.5 5.0 mA Output Open,
Current V
F
= -3.0 to +0.8 V
Threshold Input I
FLH
HCPL-3120 2.3 5.0 mA I
O
= 0 mA, 9, 15,
Current Low to
HCPL-J312 1.0
V
O
> 5 V 21
High
HCNW3120 2.3 8.0
Threshold Input V
FHL
0.8 V
Voltage High to
Low
Input Forward V
F
HCPL-3120 1.2 1.5 1.8 V I
F
= 10 mA 16
Voltage
HCPL-J312 1.6 1.95
HCNW3120
Temperature ∆V
F
/∆T
A
HCPL-3120 -1.6 mV/°C I
F
= 10 mA
Coecient of
HCPL-J312 -1.3
Forward Voltage
HCNW3120
Input Reverse BV
R
HCPL-3120 5 V I
R
= 10 µA
Breakdown
HCPL-J312 3 I
R
= 100 µA
Voltage
HCNW3120
Input Capacitance C
IN
HCPL-3120 60 pF f = 1 MHz,
HCPL-J312 70
V
F
= 0 V
HCNW3120
UVLO Threshold V
UVLO+
11.0 12.3 13.5 V V
O
> 5 V, 22,
I
F
= 10 mA 34
V
UVLO–
9.5 10.7 12.0
UVLO Hysteresis UVLO
HYS
1.6
*All typical values at T