Datasheet

7
Figure 10. Maximum Forward Current vs. Ambient Temperature.
Derated based on T
JMAX
= 125°C, Rq
J-A
= 20°C/W, 25°C/W and 30°C/W.
AlInGaP
Figure 11. Maximum Forward Current vs. Metal Slug Temperature.
Derated based on T
JMAX
= 125°C, Rq
J-MS
= 10°C/W.
Figure 8. Relative Light Output vs. Junction Temperature. Figure 9. Forward Voltage Shift vs. Junction Temperature.
0
100
200
300
400
500
600
700
800
0 20 40 60 80 100 120 140
AMBIENT TEMPERATURE, T
A
- °C
MAX ALLOWABLE DC CURRENT - mA
0
100
200
300
400
500
600
700
800
0 20 40 60 80 100 120 140
METAL SLUG TEMPERATURE, T
MS
- °C
MAX ALLOWABLE DC CURRENT - mA
Rθ
J-A
= 20°C/W
Rθ
J-A
= 25°C/W
Rθ
J-A
= 30°C/W
Rθ
J-MS
= 10°C/W
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
25 50 75 100 125
AMBER
RED
RED-ORANGE
-0.25
-0.20
-0.15
-0.10
-0.05
0.00
0.05
25 50 75 100 125
AMBER
RED
RED ORANGE
JUNCTION TEMPERATURE, T
J
-°C
RELATIVE LIGHT OUTPUT - %
(NORMALIZED AT 25 °C)
JUNCTION TEMPERATURE, T
J
-°C
FORWARD VOLTAGE SHIFT - V
(NORMALIZED AT 25°C)