Datasheet
3
Absolute Maximum Rating, T
J
= 25 °C
Parameter Red and Amber Blue and Green Unit
DC Forward Current
[1]
50 30 mA
Peak Forward Current 100
[2]
100
[3]
mA
Power Dissipation 120 114 mW
Reverse Voltage
5 (I
R
= 100 μA)
[4]
5 (I
R
= 10 μA)
[4]
V
LED Junction Temperature 110
°C
Operating Temperature Range -40 to +85
°C
Storage Temperature Range -40 to +100
°C
Notes:
1. Derate linearly as shown in Figure 4 and Figure 9.
2. Duty Factor 30%, frequency 1 kHz.
3. Duty Factor 10%, frequency 1 kHz.
4. Indicates product nal testing; long-term reverse bias is not recommended.
Electrical / Optical Characteristics, T
J
= 25 °C
Parameter Symbol Min. Typ. Max. Units Test Conditions
Forward Voltage
Red
Amber
Green
Blue
V
F
1.8
1.8
2.8
2.8
2.1
2.1
3.2
3.2
2.4
2.4
3.8
3.8
V I
F
= 20 mA
Reverse Voltage
Red & Amber
Green & Blue
V
R
5
5
V I
F
= 100 μA
I
F
= 10 μA
Dominant Wavelength
[1]
Red
Amber
Green
Blue
λ
d
618.0
584.5
519.0
460.0
626.0
590.0
525.0
470.0
630.0
594.5
539.0
480.0
I
F
= 20 mA
Peak Wavelength
Red
Amber
Green
Blue
λ
PEAK
634
594
516
464
nm Peak of Wavelength of Spectral
Distribution at I
F
= 20 mA
Thermal Resistance
Rθ
J-PIN
130
°C/W
LED Junction-to-Pin
Luminous Ecacy
[2]
Red
Amber
Green
Blue
η
V
200
520
530
65
lm/W Emitted Luminous Power/Emitted
Radiant Power
Thermal coecient of λ
d
Red
Amber
Green
Blue
0.059
0.103
0.028
0.024
nm/°C I
F
= 20 mA ; +25 °C ≤ T
J
≤ +100 °C
Notes:
1. The dominant wavelength is derived from the chromaticity diagram and represents the color of the lamp.
2. The radiant intensity, I
e
in watts per steradian, may be found from the equation I
e
= I
V
/η
V
where I
V
is the luminous intensity in candelas and η
V
is
the luminous ecacy in lumens/watt.