IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (ACPL-W611/ ACPL-P611 Option 060)
Description Symbol
ACPL-P611
Option 060
ACPL-W611
Option 060 Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
rms
I – IV I – IV
for rated mains voltage ≤ 300 V
rms
I – IV I – IV
for rated mains voltage ≤ 450 V
rms
I – III I – III
for rated mains voltage ≤ 600 V
rms
I – III I – III
for rated mains voltage ≤ 1000 V
rms
I – III
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
891 1140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test
with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1670 2137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.5=V
PR
, Type and Sample Test,
t
m
=60 sec, Partial discharge < 5 pC
V
PR
1336 1710 V
peak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 10 sec)
V
IOTM
6000 6000 V
peak
Safety-limiting values – maximum values
allowed in the event of a failure
Case Temperature T
S
175 175 °C
Input Current** I
S, INPUT
230 230 mA
Output Power** P
S, OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
>10
9
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test proles.
** Refer to the following gure for dependence of P
S
and I
S
on ambient temperature.
POWER OUTPUT – P
S
(mW), INPUT CURRENT – I
S
(mA)
0
0
T
S
– CASE TEMPERATURE – °C
20017550
400
12525 75 100 150
600
200
100
300
500
700
P
S
(mW)
I
S
(mA)