4
Recommended Solder Reow Thermal Prole
Recommended Pb-Free IR Prole Regulatory Information
The ACPL-W611 and ACPL-P611 is approved/pending ap-
proval by the following organizations:
IEC/EN/DIN EN 60747-5-2 (Option 060 only)
Pending Approval under:
IEC 60747-5-2 :1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
UL
Approval under UL 1577, component recognition
program up to V
ISO
= 3750 V
RMS
. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
Note: Use of non chlorine-activated uxes is highly recommended.
Note: Use of non chlorine-activated uxes is highly recommended.
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C