Datasheet

9
Parameter Sym. Device Min. Typ. Units Test Conditions Fig. Note
Output High
Level Common
Mode Transient
Immunity
|CM
H
| ACPL-W60L
ACPL-K63L
15 25
kV/ms
V
CC
= 3.3 V, I
F
= 0 mA,
V
O(MIN)
= 2 V,
R
L
= 350 W,
T
A
= 25°C,
V
CM
= 1000 V and V
CM
= 10 V
9 10, 12
Output Low
Level Common
Mode Transient
Immunity
|CM
L
| ACPL-W60L
ACPL-K63L
15 25
kV/ms
V
CC
= 3.3 V, I
F
= 7.5 mA,
V
O(MAX)
= 0.8 V,
R
L
= 350 W,
T
A
= 25°C,
V
CM
= 1000 V and V
CM
= 10 V
9 10, 12
Output High
Level Common
Mode Transient
Immunity
|CM
H
| ACPL-W60L
ACPL-K63L
10 15
kV/ms
V
CC
= 5 V, I
F
= 0 mA,
V
O(MIN)
= 2 V,
R
L
= 350 W,
T
A
= 25°C,
V
CM
= 1000 V
9 10, 12
Output Low
Level Common
Mode Transient
Immunity
|CM
L
| ACPL-W60L
ACPL-K63L
10 15 kV/ms
V
CC
= 5 V, I
F
= 7.5 mA,
V
O(MAX)
= 0.8 V,
R
L
= 350 W,
T
A
= 25°C,
V
CM
= 1000 V
9 11, 12