Datasheet
5
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (ACPL-P314/W314 Option 060)
Table 2. Insulation and Safety Related Specications
Description Symbol Characteristic Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage £ 150V
rms
for rated mains voltage £ 300V
rms
for rated mains voltage £ 600V
rms
I - IV
I - III
I - II
Climatic Classication 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
630 V
peak
Input to Output Test Voltage, Method b*V
IORM
x 1.875=V
PR
, 100% Production Test
with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1181 V
peak
Input to Output Test Voltage, Method a*V
IORM
x 1.5=V
PR
, Type and Sample Test,
t
m
=60 sec, Partial discharge < 5 pC
V
PR
945 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 10 sec) V
IOTM
6000 V
peak
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current**
Output Power**
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
Parameter Symbol
ACPL
UNITS
Conditions
P314 W314
Minimum External Air Gap
(External Clearance)
L(101) 7.0 8.0 mm Measured from input terminals to output termi-
nals, shortest distance through air.
Minimum External Tracking
(External Creepage)
L(102) 8.0 8.0 mm Measured from input terminals to output termi-
nals, shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 0.08 mm Through insulation distance conductor to con-
ductor, usually the straight line distance thick-
ness between the emitter and detector.
Minimum Internal Tracking
(Internal Creepage)
NA NA mm Measured from input terminals to output termi-
nals, along internal cavity.
Tracking Resistance
(Comparative Tracking Index)
CTI >175 >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
* Refer to the optocoupler section of the Isolation and Control
Components Designer’s Catalog, under Product Safety Regulations
section, (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test proles.
** Refer to the following gure for dependence of P
S
and I
S
on ambient
temperature.