Datasheet

7
Table 6. Switching Specications (AC)
All typical values are at T
A
= 25 °C, V
CC
- V
EE
= 10 V, V
EE
= Ground. All minimum and maximum specications are at rec-
ommended operating conditions (T
A
= -40 to 105 °C, I
F(ON)
= 7 to 11 mA, V
F(OFF)
= -3.6 to 0.8 V, V
EE
= Ground), unless
otherwise noted.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay Time to
High Output Level
t
PLH
30 55 120 ns Rg = 10 Ω,
Cg = 10 nF,
f = 200 kHz ,
Duty Cycle = 50%,
V
CC
= 10V
14, 15,
16, 17
Propagation Delay Time to Low
Output Level
t
PHL
30 55 120 ns
Pulse Width Distortion PWD 0 50 ns 9
Propagation Delay Dierence
Between Any Two Parts
PDD
(t
PHL
- t
PLH
)
-50 50 ns 24, 25 10
Propagation Delay Skew t
PSK
40 ns 11
Rise Time t
R
8 30 ns Cg = 1 nF,
f = 200 kHz ,
Duty Cycle = 50%,
V
CC
= 10V
18, 20
Fall Time t
F
8 30 ns
Output High Level Common
Mode Transient Immunity
|CM
H
| 50 70 kV/µs T
A
= 25 °C, I
F
= 9 mA,
V
CC
= 20 V, V
CM
= 1500 V
with split resistors
21 12, 13
Output Low Level Common
Mode Transient Immunity
|CM
L
| 50 70 kV/µs T
A
= 25°C, V
F
= 0 V,
V
CC
= 20 V, V
CM
= 1500 V
with split resistors
14, 15
Table 7. Package Characteristics
All typical values are at T
A
= 25 °C. All minimum/maximum specications are at recommended operating conditions,
unless otherwise noted.
Parameter Symbol Device Min. Typ. Max. Units Test Conditions Fig. Note
Input-Output Momentary
Withstand Voltage*
V
ISO
ACPL-P346 3750 V
RMS
RH < 50%,
t = 1 min., T
A
= 25 °C
15,17
ACPL-W346 5000 V
RMS
RH < 50%,
t = 1 min., T
A
= 25 °C
16,18
Input-Output Resistance R
I-O
>50
12
V
I-O
= 500 V
DC
17
Input-Output Capacitance C
I-O
0.6 pF f =1 MHz
LED-to-Ambient
Thermal Resistance
R
11
135
°C/W 18
LED-to-Detector
Thermal Resistance
R
12
27
Detector-to-LED
Thermal Resistance
R
21
39
Detector-to-Ambient
Thermal Resistance
R
22
47
* The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating, refer to your equipment level safety specication or Avago Technologies Application Note 1074
entitled “Optocoupler Input-Output Endurance Voltage.