Datasheet

4
Recommended Pb-Free IR Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-P346/W346 is approved by the following organizations:
UL Recognized under UL 1577, component recognition program up to V
ISO
= 3750 V
RMS
(ACPL-
P346) and V
ISO
= 5000 V
RMS
(ACPL-W346).
CSA CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-5
(Option 060 Only)
Maximum Working Insulation Voltage V
IORM
= 891V
peak
(ACPL-P346) and V
IORM
= 1140
V
peak
(ACPL-W346)
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description Symbol
ACPL-P346
Option 060
ACPL-W346
Option 060 Unit
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage 150 Vrms
for rated mains voltage 300 Vrms
for rated mains voltage 450 Vrms
for rated mains voltage 600 Vrms
for rated mains voltage 1000 Vrms
I – IV
I – IV
I – III
I – III
I – IV
I – IV
I – IV
I – IV
I – III
Climatic Classication 40/105/21 40/105/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
891 1140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
V
PR
1671 2137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6=V
PR
, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
V
PR
1426 1824 V
peak
Highest Allowable Overvoltage*
(Transient Overvoltage tini = 60 sec)
V
IOTM
6000 8000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature TS 175 175 °C
Input Current I
S, INPUT
230 230 mA
Output Power P
S, OUTPUT
600 600 mW
Insulation Resistance at TS, V
IO
= 500 V RS >10
9
>10
9
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test proles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classication is Class A in accordance with CECC 00802.