Datasheet
4
Recommended Pb-Free IR Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-P346/W346 is approved by the following organizations:
UL Recognized under UL 1577, component recognition program up to V
ISO
= 3750 V
RMS
(ACPL-
P346) and V
ISO
= 5000 V
RMS
(ACPL-W346).
CSA CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-5
(Option 060 Only)
Maximum Working Insulation Voltage V
IORM
= 891V
peak
(ACPL-P346) and V
IORM
= 1140
V
peak
(ACPL-W346)
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description Symbol
ACPL-P346
Option 060
ACPL-W346
Option 060 Unit
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
I – IV
I – IV
I – III
I – III
I – IV
I – IV
I – IV
I – IV
I – III
Climatic Classication 40/105/21 40/105/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
891 1140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
V
PR
1671 2137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6=V
PR
, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
V
PR
1426 1824 V
peak
Highest Allowable Overvoltage*
(Transient Overvoltage tini = 60 sec)
V
IOTM
6000 8000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature TS 175 175 °C
Input Current I
S, INPUT
230 230 mA
Output Power P
S, OUTPUT
600 600 mW
Insulation Resistance at TS, V
IO
= 500 V RS >10
9
>10
9
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test proles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classication is Class A in accordance with CECC 00802.