Datasheet
5
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Power Supply Voltage V
CC
4.5 30 Volts
Output Voltage V
O
0 30 Volts
Input Current (ON) I
F(on)
10 20 mA
Input Voltage (OFF) V
F(o)
-5 0.8 V
Operating Temperature T
A
-40 125 °C
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units
Storage Temperature T
S
-55 150 °C
Operating Temperature T
A
-40 125 °C
Average Input Current
[1]
I
F(avg)
20 mA
Peak Input Current
[2]
I
F(peak)
40 mA
(50% duty cycle, <1 ms pulse width)
Peak Transient Input Current I
F(tran)
1.0 A
(<1 µs pulse width, 300 pps)
Reverse Input Voltage (Pin 3-1) V
R
5 Volts
Average Output Current (Pin 5) I
O(avg)
15 mA
Output Voltage (Pin 5-4) V
O
-0.5 30 Volts
Supply Voltage (Pin 6-4) V
CC
-0.5 30 Volts
Output Power Dissipation
[3]
P
O
100 mW
Total Power Dissipation
[4]
P
T
145 mW
Infrared and Vapor Phase Reow Temperature See Reow Thermal Prole below.