Datasheet

6
IEC/EN 60747-5-5 Insulation Characteristics* (Option 060 and 560 only)
Description Symbol
Characteristic
Unit
ACPL-M21L/
024L/021L
ACPL-W21L/
K24L
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
for rated mains voltage ≤ 1000 V
rms
I – IV
I – III
I – II
I – IV
I – IV
I – III
I – III
Climatic Classication 55/105/21 55/105/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
567 1140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test
with t
m
= 1 sec, Partial discharge < 5 pC
V
PR
1063 2137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test,
t
m
= 10 sec, Partial discharge < 5 pC
V
PR
896 1824 V
peak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 60 sec)
V
IOTM
6000 8000 V
peak
Safety-limiting values – maximum values allowed in the
event of a failure.
Case Temperature
Input Current**
Output Power**
T
S
I
S, INPUT
P
S, OUTPUT
150
150
600
175
230
600
°C
mA
mW
Insulation Resistance at TS, V
IO
= 500 V R
S
>10
9
>10
9
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test proles.
** Refer to the following gure for dependence of P
S
and I
S
on ambient temperature.
Absolute Maximum Ratings
Parameter Symbol Min Max Units Condition
Storage Temperature T
S
-55 125
°C
Operating Temperature T
A
-40 105
°C
Reverse Input Voltage V
R
5 V
Supply Voltage V
DD
6.5 V
Average Forward Input Current I
F
8 mA
Peak Forward Input Current I
F(TRAN)
1 A
≤ 1 μs Pulse Width,
< 300 pulses per second
Output Current I
O
10 mA At max V
DD
Output Voltage V
O
-0.5 V
DD
+0.5 V
Lead Solder Temperature T
LS
260 °C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Package Outline Drawings section