Datasheet
7
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description Symbol
ACPL-3130
Option 060 ACPL-J313 ACNW3130 Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V≤ 150 V 150 V
rms
for rated mains voltage ≤ 300 V≤ 300 V 300 V
rms
for rated mains voltage ≤ 450 V≤ 450 V 450 V
rms
for rated mains voltage ≤ 600 V≤ 600 V 600 V
rms
for rated mains voltage ≤ 1000 V≤ 1000 V 1000 V
rms
I – IV
I – IV
I – III
I – IV
I – IV
I – III
I – III
I – IV
I – IV
I – IV
I – IV
I – III
Climatic Classication 55/100/21 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2 2 2
Maximum Working Insulation Voltage V
IORM
630 891 1414 V
peak
Input to Output Test Voltage, Method b* V
IORM
x 1.875=V
PR
,
100% Production Test with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1181 1670 2652 V
peak
Input to Output Test Voltage, Method a* V
IORM
x 1.5=V
PR
,
Type and Sample Test, t
m
=60 sec, Partial discharge < 5 pC
V
PR
945 1336 2121 V
peak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 10 sec)
V
IOTM
6000 6000 8000 V
peak
Safety-limiting values – maximum values allowed in the event of a
failure, also see Figure 41 and 42.
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
175
400
600
150
400
700
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
>10
9
>10
9
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test proles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classication is Class A in accordance with CECC 00802.
Table 2. Insulation and Safety Related Specications
Parameter Symbol ACPL-3130 ACPL-J313 ACNW3130 Units Conditions
Minimum External Air
Gap (Clearance)
L(101) 7.1 7.4 9.6 mm Measured from input terminals to output
terminals, shortest distance through air.
Minimum External
Tracking (Creepage)
L(102) 7.4 8.0 10.0 mm Measured from input terminals to output
terminals, shortest distance path along body.
Minimum Internal
Plastic Gap (Internal
Clearance)
0.08 0.5 1.0 mm Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Tracking Resistance
(Comparative Tracking
Index)
CTI > 175 > 175 > 200 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
All Avago data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as a starting
point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit board, minimum
creepage and clearance requirements must be met as specied for individual equipment standards. For creepage, the shortest distance path along
the surface of a printed circuit board between the solder llets of the input and output leads must be considered. There are recommended techniques
such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances. Creepage and clearance distances
will also change depending on factors such as pollution degree and insulation level.