Figure 41. Thermal Derating Curve, Dependence of Safety Limiting Value
with Case Temperature per IEC/EN/DIN EN 60747-5-2 for ACPL-3130 (op-
tion 060) and ACPL-J313.
Figure 42. Thermal Derating Curve, Dependence of Safety Limiting Value
with Case Temperature per IEC/EN/DIN EN 60747-5-2 for ACNW3130.
Figure 40. Waveforms for Dead Time.
t
PLH
MIN
MAXIMUM DEAD TIME
(DUE TO OPTOCOUPLER)
= (t
PHL MAX
-
t
PHL MIN
) + (t
PLH MAX
-
t
PLH MIN
)
= (t
PHL MAX
-
t
PLH MIN
) - (t
PHL MIN
-
t
PLH MAX
)
= PDD* MAX - PDD* MIN
*PDD = PROPAGATION DELAY DIFFERENCE
NOTE: FOR DEAD TIME AND PDD CALCULATIONS ALL PROPAGATION
DELAYS ARE TAKEN AT THE SAME TEMPERATURE AND TEST CONDITIONS.
V
OUT1
I
LED2
V
OUT2
I
LED1
Q1 ON
Q2 OFF
Q1 OFF
Q2 ON
t
PHL MIN
t
PHL MAX
t
PLH MAX
PDD* MAX
(t
PHL-
t
PLH
)
MAX
OUTPUT POWER - P
S
, INPUT CURRENT - I
S
0
0
T
S
- CASE TEMPERATURE - °C
200
600
400
25
800
50 75 100
200
150 175
P
S
(mW)
125
100
300
500
700
I
S
(mA) FOR ACPL-3130
OPTION 060
I
S
(mA) FOR ACPL-J313
OUTPUT POWER - P
S
, INPUT CURRENT - I
S
0
0
T
S
- CASE TEMPERATURE - °C
175
1000
50
400
12525 75 100 150
600
800
200
100
300
500
700
900
P
S
(mW)
I
S
(mA)
For product information and a complete list of distributors, please go to our web site: www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies Limited in the United States and other countries.
Data subject to change. Copyright © 2005-2008 Avago Technologies, Limited. All rights reserved. Obsoletes AV01-0630EN