Datasheet
10
Table 6. Switching Specications (AC)
Over recommended operating conditions (T
A
= -40 to 100°C, for ACPL-3130,ACPL-J313 I
F(ON)
= 7 to 16mA, for ACNW3130
I
F(ON)
= 10 to 16mA, V
F(OFF)
= -3.6 to 0.8 V, V
CC
= 15 to 30 V, V
EE
= Ground) unless otherwise specied. All typical values at
T
A
= 25°C and V
CC
- V
EE
= 30 V, unless otherwise noted.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay Time
to High Output Level
t
PLH
0.10 0.30 0.50 µs
Rg = 10 W,
Cg = 10 nF,
f = 10 kHz,
Duty Cycle = 50%
12,13,
14, 15,
16, 27
16
Propagation Delay Time
to Low Output Level
t
PHL
0.10 0.30 0.50 µs
Pulse Width Distortion PWD 0.3 µs 17
Propagation Delay
Dierence Between Any
Two Parts or Channels
PDD
(t
PHL
– t
PLH
) -0.35 0.35 µs 39, 40 12
Rise Time t
R
0.1 µs 27
Fall Time t
F
0.1 µs
UVLO Turn On Delay t
UVLO ON
0.8 µs I
F
= 10 mA, V
O
> 5 V 26
UVLO Turn O Delay t
UVLO OFF
0.6 µs I
F
= 10 mA, V
O
> 5 V 26
Output High Level
Common Mode
Transient Immunity
|CM
H
| 40 50 kV/
µs
T
A
= 25°C,
I
F
= 10 to 16 mA,
V
CM
= 1500 V, V
CC
= 30 V
27 13, 14
Output Low Level
Common Mode
Transient Immunity
|CM
L
| 40 50 kV/
µs
T
A
= 25°C, V
F
= 0 V,
V
CM
= 1500 V
V
CC
= 30 V
27 13, 15
Table 7. Package Characteristics
Over recommended temperature (T
A
= -40 to 100°C) unless otherwise specied. All typicals at T
A
= 25°C.
Parameter Symbol Device Min. Typ. Max. Units Test Conditions Fig. Note
Input-Output
Momentary
Withstand Voltage**
V
ISO
ACPL-3130 3750 V
rms
RH < 50%,
t = 1 min.,
T
A
= 25°C
8, 11
ACPL-J313 3750 V
rms
9, 11
ACNW3130 5000 V
rms
10, 11
Resistance
(Input-Output)
R
I-O
ACPL-3130 10
12
W
V
I-O
= 500 V 11
ACPL-J313 10
12
W
V
I-O
= 500 V
ACNW3130 10
12
10
13
W
V
I-O
= 500 V,
T
A
= 25°C
10
11
W
V
I-O
= 500 V,
T
A
= 100°C
Capacitance
(Input-Output)
C
I-O
ACPL-3130 0.6 pF Freq=1 MHz
ACPL-J313 0.8 pF Freq=1 MHz
ACNW3130 0.5 0.6 pF Freq=1 MHz
LED-to-Case
Thermal Resistance
q
LC
467 °C/W Thermocouple
located at center
underside of package
32
LED-to-Detector
Thermal Resistance
q
LD
442 °C/W 32
Detector-to-Case
Thermal Resistance
q
DC
126 °C/W 32
** The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specication or Avago Application