Datasheet
7
Table 7. Electrical Specications (continued)
Unless otherwise noted, T
A
= -40° C to +105° C, V
DD1
= 4.5 V to 5.5 V, V
DD2
= 3.3 V to 5.5 V, V
IN
= 0 – 2 V, and V
SD
= 0 V.
Parameter Symbol Min. Typ.
[1]
Max. Unit Test Conditions/Notes Fig.
AC CHARACTERISTICS
Vout Noise N
out
0.013 mV
rms
Vin = 0 V;
Output low-pass ltered
to 180 KHz. Note 3.
12
Small-Signal Bandwidth (-3 dB) f
–3 dB
70 100 kHz Guaranteed by design
Input to Output
Propagation Delay
50%-10% t
PD10
2.2 3.0
ms
Step input. 18
50%-50% t
PD50
3.7 5.5
ms
Step input. 18
50%-90% t
PD90
5.3 6.5
ms
Step input. 18
Output Rise/Fall Time (10%-90%) t
R/F
2.7 4.0
ms
Step input (t
PD90
- t
PD10
)
Shutdown Delay t
SD
25 40
ms
Vin = 2 V 17
Enable Delay t
ON
150 200
ms
Common Mode Transient Immunity CMTI 10 15
kV/ms
V
CM
= 1 kV, T
A
= 25° C
Power Supply Rejection PSR -78 dB 1 Vpp 1 kHz sine wave
ripple on V
DD1
,
dierential output
POWER SUPPLIES
Input Side Supply Current I
DD1
10.5 15 mA V
SD
= 0 V
15
mA
V
SD
= 5 V
I
DD2
6.5 12 mA 5 V supply
6.1 11 mA 3.3 V supply
Notes:
1. All Typical values are under Typical Operating Conditions at T
A
= 25° C, V
DD1
= 5 V, V
DD2
= 5 V.
2. Gain is dened as the slope of the best-t line of dierential output voltage (V
OUT+
– V
OUT-
) versus input voltage over the nominal range, with oset
error adjusted.
3. Noise is measured at the output of the dierential to single ended post amplier.
4. When is V
SD
= 5 V or when shutdown is enabled, V
out+
is close to 0V and V
out-
is at close to 2.46 V.
This is similar to when VDD1 is not supplied.
Table 8. Package Characteristics
Parameter Symbol Min Typ Max Units Test Conditions Note
Input-Output Momentary
Withstand Voltage
V
ISO
5000 Vrms RH < 50%, t = 1 min.,
T
A
= 25° C
1, 2
Resistance (Input-Output) R
I-O
> 10
12
W
V
I-O
= 500 V
DC
3
Capacitance (Input-Output) C
I-O
0.5 pF f = 1 MHz 3
Notes:
1. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 Vrms for 1 second (leakage detection
current limit, I
I-O
≤ 5 mA). This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-
5-5 Insulation Characteristic Table.
2. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating, refer to the IEC/EN/DIN EN 60747-5-5 insulation characteristics table and your equipment level
safety specication.
3. This is a two-terminal measurement: pins 1–4 are shorted together and pins 5–8 are shorted together.