Specifications

e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
11
SS 16.2 Installation and Operation Manual
SPECIFICATIONS
STATUS
The status signals from the front panel indicator LEDs are supplied through the
“REMOTE” control connector as individual open collectors. This may provide sta-
tus to a remote control point to indicate which source is selected. The status output
for the selected output will go low, providing a return for an LED indicator or
TTL/CMOS logic. External pull-up resistors may be required in some installations.
J3 “REMOTE” Status pin numbers (Open Collectors):
19 – Audio Activity LED/Open collector for output 1
20 – Status number 1 21 – Status number 2
22 – Status number 3 23 – Status number 4
24 – Status number 5 25 – Status number 6
26 – Status number 7 27 – Status number 8
28 – Status number 9 29 – Status number 10
30 – Status number 11 31 – Status number 12
32 – Status number 13 33 – Status number 14
34 – Status number 15 35 – Status number 16
36 – Audio Activity LED/Open collector for output 2
SPECIFICATIONS
WEBSITE:
Visit our web site for
product updates and
additional information
INPUTS/OUTPUTS: Any input level and impedance can be used. Inputs
may be balanced or unbalanced. Output levels,
impedance, distortion, noise and balancing will
match that of the selected input.
SWITCHING METHOD: Passive.
Sealed relays utilizing 2-form-C Bifurcated-
Crossbar silver alloy with gold overlay contacts.
LOGIC: Flash Microprocessor, non-volatile memory.
OPERATION CONTROL: Front Panel - Momentary switches.
Remote - Momentary closure to ground or 5 Volt
TTL/CMOS Logic levels.
Serial - RS-232c, 6P4C modular w/ 9 pin-D-Sub
adapter, 1200, 2400, 4800, 9600, 19200, 38400 /
8,N,1
STATUS: Front Panel - Indicator LED in Switch.
Remote “Act” LED’s Trip level set at –35db below Ref.
Remote
- Open collector outputs, limit current to 50ma
per output. Pull-ups may be required.