Specifications

e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
10
SS 16.2 Installation and Operation Manual
INSTALLATION
STEP 4: MOUNTING
Mount the unit in a rack or desktop, allowing adequate airflow for cooling.
STEP 5: CONNECT YOUR EQUIPMENT
The 16 x 2 interfaces to your equipment (sources and loads) through the rear panel
pluggable screw terminals. Follow the legends for the desired audio input and out-
put connections, which appear on the rear side of the printed circuit board and also
on the layout drawing on the last page of this manual. Remove each screw termi-
nal, strip each conductor and insert the conductor into the terminal and screw down
the capture screw. The terminals accommodate wire sizes from 16 - 28 AWG solid
or stranded wire.
STEP 6: DESIGNATION STRIP
The designation strip is provided in order to write the source descriptions under each
source switch.
STEP 7: SERIAL OPERATION
The supplied modular cable and 9 pin D-sub adapter may be connected to the
16 x 2’s rear panel modular connector. Plug in the D-sub adapter into your com-
puters serial port. Plug the supplied wall transformer into a source of 117 vac and
the cable end of the transformer into the power receptacle on the 16 x 2. The pro-
tocol is as follows: 1200, 2400, 4800, 9600, 19200, 38400, 8N1. Flow Control
should be NONE, emulation ANSI and the mode should be DIRECT TO COMx
(x = the available com port). The default is 9600,8,N,1.
Serial string example: *1162 Address for unit 1, with input sixteen routed to
output two.
REMOTE CONTROL CONNECTOR PINOUTS
J3 Remote Switch Pin numbers:
1 – Switch number 1 2 – Switch number 2
3 – Switch number 3 4 – Switch number 4
5 – Switch number 5 6 – Switch number 6
7 – Switch number 7 8 – Switch number 8
9 – Switch number 9 10 – Switch number 10
11 – Switch number 11 12 – Switch number 12
13 – Switch number 13 14 – Switch number 14
15 – Switch number 15 16 – Switch number 16
17 – Mute input 18 – Output 2 select
37 – Ground