DESCRIPTION
RS232 Serial Port
The AC 16.2’s serial communication is supplied with a multi-drop RS-232 port,
allowing up to four ACS 16.2’s on the same computers serial port. Commands may
be entered either via a menu (with unit ID 0 only) (menu mode) or a short form code
(ASCII serial string-burst mode). The command to enter menu mode is: *0MM. The
menu mode displays certain parameters, and allows for the control and/or configura-
tion of most switcher functions. All commands and responses use normal ASCII char-
acters, facilitating scripting. A burst mode command starts with an asterisk (*) fol-
lowed by the device (ID) address as a single decimal digit, then the command.
User Programming
The ACS 16.2 programming is stored in non-volatile memory. Configuration is set
with selection dipswitches and computer commands.