Specifications

e-mail: support@broadcasttools.com voice: 360.854.9559 fax: 866.783.1742
14
ACS 16.2 Installation and Operation Manual
OPERATION
OPERATION GUIDELINES
ACS 16.2 Front Panel LED’s
ACS 16.2 Front Panel Channel selection knob and Switch operation
Front Panel LED’s Number Activation Event/Mode Activation Behavior
Of LED’s
Input connected to “OP 1” 16 Green State of audio connections. ON if connected
Input connected to “OP 2” 16 Red State of audio connections. ON if connected
“PWR/HB” 1 Green Valid power and unit operational. ON, but flickers with serial activity.
“PIP” (Triggers) input activated. 1 Yellow Any valid “PIP” / Trigger input, when
enabled.
Flickers with PIP input activity.
“SS 1” Silence alarm on output ONE. 1 Red Duration of silence on output ONE. In an alarm condition when ON.
“SS 2”, Silence alarm on output TWO. 1 Red Duration of silence on output TWO. In an alarm condition when ON.
“OP2”, VU meter and headphone selection. 1 Green When illuminated, the VU meters and
headphone amplifier is monitoring
output TWO.
ON, Output TWO. OFF, Output ONE.
Action Result
“SELECT” knob. Twist to sequence though inputs one
through sixteen for each output.
Selects the desired input to output. As you twist the knob, the LED will
display your input to output position. By pressing the “TAKE” push but-
ton, the LED will stop flashing and go solid. The input is now active.
Repeat the process to turn an input off.
“TAKE” button. Turn inputs on or off. Pressing the “TAKE” when an input is selected using the “SELECT”
knob will turn the input on or off for the designated output.
“MON SELECT”. Push to toggle between output one and
two monitoring.
Switches headphone/VU monitoring between output one and two.
“HDPH LEVEL”. Adjusts the headphone level. Adjusts the headphone output level.