Operator`s manual
29
MicroSYNC CONFIGURE Select
The MicroSYNC card (VS-2400) can be configured with a number of CONFIGURATION functions. To change a
CONFIGURATION function, perform the following steps:
1. Choose the ES-2200 channel containing the MicroSYNC card using the UNIT 1/ UNIT 2 SELECT button.
2. Place the MicroSYNC card into CONFIGURATION mode by pressing the CONFIGURE button for one second so
that the CONFIGURE LEDs are both flashing. (Red and Green LEDs)
3. There are ten set-up options. Select the setup option by pressing the appropriate button. Setup functions are labeled
in blue, located below the push buttons.
4. Choose a mode for the selected configuration function by turning the rotary shaft encoder knob. Modes are
indicated by the number (1-5) legends located to the left of the LED level display. The default value for each setup
option is 1. The following table details the various configuration function choices.
Remember, after changing one or more of these MicroSYNC configure modes, the unit will remain in
CONFIGURATION mode until you press the CONFIGURE button to return the synchronizer to normal operation.
Once the CONFIGURE LEDs are extinguished, the buttons return to their primary functions, denoted by the black
legend located above each button.
NOTE: In normal mode, If the red LED on the CONFIGURE button flashes, this indicates that there is no valid NTSC
signal feeding the synchronizer or that the MicroSYNC is in BYPASS mode.