Operator`s manual

27
Memory
These functions are shift functions below the Proc Amp controls.
The ES-2200S stores all current settings, such as Proc-amp levels and system timing, in its own non-volatile memory.
The memory is automatically updated once every three seconds. These settings are automatically recalled and
transferred to the resident MicroSYNC card on power up, so that system timing and Proc-amp levels are not lost.
System timing information is stored separately for each resident card. Proc-amp levels are stored with respect to each
MicroSYNC. Memory functions all appear as shift functions on the Proc Amp buttons.
STORE
The MEMORY STORE function causes the current proc amp settings to be saved in non-volatile memory in the ES-
2200S. These settings may later be recalled using the recall function. Holding in the Video button for approximately
one second activates this function. When this function occurs, the front panel proc amp LEDs will flash for one second.
RECALL
The MEMORY RECALL function is used to recall settings previously stored using the store function. Holding in the
BLACK button for approximately one second activates this function. When this function is occurs, the front panel proc
amp LEDs will flash for one second.
PREVIOUS
The MEMORY PREVIOUS function is used to return the proc amp settings to those present before a memory recall or
unity function. Holding in the CHROMA button for approximately one second activates this function. When this
function occurs, the front panel proc amp LEDs will flash for one second.
MEMORY UNITY
The MEMORY UNITY function returns all proc amp, and color balance settings to the factory preset values. Holding
in the HUE button for approximately one second activates this function. When this function occurs, the front panel proc
amp LEDs will flash for one second.
Function
PROCESS and BYPASS are primary functions.
PROCESS
When this button is selected, the MicroSYNC is in its normal operating mode.
BYPASS
When this button is pressed until the LED begins to flash, the MicroSYNC will route its video input directly to its
video output connector. While the MicroSYNC is in bypass mode, all front panel functions are disabled except for the
unit select button. Also the BYPASS LED and the CONFIGURE red LED will continuously flash.
Both PROCESS and BYPASS LEDs are distinguished when the MicroSYNC is configured for force black out.