Specifications

e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
16
SS 4x4 Installation and Operation Manual
OPERATION
Glossary Of Command Notation
Character String Meaning Allowable Values
u Unit ID 0-3
ii Input Number 01-04
o Output Number 1-4
r Output Relay 1-4
o Open Collector 1-4
Set-up Commands
*uMM - Open up Menu
*uCEx - Enable Error and Good Responses - Where x = Y to enable and N = disable.
In this mode, when a command is sent that is in error, the unit will reply (possibly
before receiving the entire command) with “EEE.” If the command is sent correct-
ly, the unit will reply with “RRR.”
*uCDEF - Set factory defaults
*uCIIttt - Set “PIP” Programmable Pulse Stretcher Input Duration = ttt: 000 –> 255
hundredths of seconds (255 = 2.55 Seconds)
*uCLx - Lock Front Panel if x is “L”. Unlock Front Panel if x is “U”
*uCPR- Power up audio state: Restore audio from power up state
*uCPS - Power up audio state: Save power up state
*uCRtt- Set Relay Momentary Pulse Length – tt: 00-99 for 00 –> 9.9 Seconds
Set-up Commands
*uCSAtttt - Set silence sensor time delay to tttt seconds (0002 – 9999), 0000 = OFF
*uCSBtttt - Set silence sensor restore delay to tttt seconds (0002 – 9999), 0000 =
OFF
Relay and Open Collector Commands
*uORrF - Unlatch output relay “r”
*uORrL - Latch output relay “r”
*uORrP - Pulse output relay “r”