Specifications

NTI VEEMUX DVI VIDEO MATRIX SWITCH
21
Additional Command Definitions for Audio Option
Command String Good Response Description
AS SW,IP,OP *<CR> AUDIO Connect One Output/User Port To Input/CPU Port
AA SW,IP *<CR> AUDIO Connect All Output/User Ports To Input/CPU Port
AO SW,OP *<CR>IP<CR> AUDIO Read Connection For Output/User Port
AM SW,OP,MU *<CR> Set Mute State For Output/User Port
AV SW,OP,VV *<CR> Set Volume Level For Output/User Port
See chart on page 21 for values
AR SW,OP *<CR>MU,VV<CR> Read Mute, Volume For Output/User Port
MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.
VV is a value between 00 to 99 (see chart below)
Set Volume Level For Output/User Port (for command string AV SW,OP,VV in chart above)
This command will set the volume of the specified AUDIO output/user port from a scale of 00 to 99, which represents a logarithmic
volume.
Serial Data (VV) Audio Volume
90 – 99 +10dB
80 0dB
60 -20dB
0 – 28 -52dB
Autostatus
When Autostatus is enabled, any output-to-input connection change in the VEEMUX will cause an Autostatus message to be sent
via RS232 to the administrator. The format of the message would be "pc SW,OP:IP<CR>"
Example of an Autostatus message:
pc 01,01:04<CR>
which means "At the switch with unit address 01, the output (01) has changed connection to input 04."
Notes: Message to the administrator will be delayed by any RS232 traffic being received by the switch from the
administrator.
Autostatus must be disabled before using SerTest or the Matrix Switcher's Control Program (page 21).
By default, Autostatus is disabled and must be manually enabled. Autostatus is also disabled any time the power to the
VEEMUX is interrupted.
Matrix Switchers Control Program For Windows 9X, NT, 2000, XP, Vista and 7
The Matrix Switchers Control Program is an easy and powerful graphical program that controls NTI matrix switches through an
RS232 interface. The Matrix Switchers Control Program is downloaded by clicking on the link "Download Matrix Switchers
Control Program" found on the web page that appears when you insert the instruction manual CD into your CD ROM drive.
To install the Matrix Switchers Control Program after downloading
1. Locate the Setup.exe in the directory the program was downloaded to and double-click on it
2. Follow the instructions on the screen
The Matrix Switchers Control Program performs best on monitors set to a screen resolution of at least 800 X 600. Instruction for
using the Matrix Switchers Control Program is available by opening "MSCP Help" in the "NTI" program group once the program
has been installed and is open on the screen.
To open "MSCP Help" from the Windows desktop
1. Click on START
2. Click on PROGRAMS
3. Click on NTI
4. Click on MSCP Help
Note: While in Scan Mode, the video radio
buttons shown on the Switch page of the
Matrix Switchers Control Program may not
be in sync with the connection changes
within the VEEMUX. Connections will
change without updating the image on the
screen.