Specifications

ee--mmaaiill::
support@broadcasttools.com
vvooiiccee::
360.854.9559
ffaaxx::
360.854.9479
9
SS 4x1 III Installation and Operation Manual
INSTALLATION
Remote Control Connector:
The front panel functions are brought out through the rear panel “REMOTE” con-
nector TB 4, providing a means of controlling the SS 4.1 III from a remote point.
The digital inputs may be connected to any remote pair of switch contacts, such as
external relays, switches, open-collectors or 5-volt logic signals.
Status:
The status signals are supplied through the “Remote” control connector as individ-
ual open collectors. The open collectors may be used to provide status to a remote
control point to indicate which source is selected. The status output for the select-
ed output will go low, providing a return for an LED indicator, TTL/CMOS logic
or relay. External pull-up resistors may be required in some installations.
Rear Panel Connectors
TB 1 --> TB 2
EVEN
Inputs Top Row
Input x – Left Input x + Left Chs
Gnd
Input x – Right Input x + Right
Input x – Left Input x + Left Chs
Gnd
Input x – Right Input x + Right
ODD Inputs Bottom Row
TB 3 Output Top Row
Output Left Output + Left Chs
Gnd
Output Right Output + Right
TB 4 Open Collector Outputs Top Row
Open
Collector 1
Open
Collector 2
Open
Collector 3
Open
Collector 4
Ground Ground
Input 1 Input 2 Input 3 Input 4 Mute Step
Remote input selection Bottom Row