Specifications
e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
10
SS 4.1 Plus Installation and Operation Manual
INSTALLATION
Remote Control
TB 4 Pin Function (DIPSw 6-7 = OFF). Function (DIPSw 6-7 = ON)
BOT 1 Silence Sensor Relay N.O. Silence Sensor Relay N.O.
BOT 2 Silence Sensor Relay CM Silence Sensor Relay CM
BOT 3 IN 1, selects channel ONE PIP 1
BOT 4 IN 2, selects channel TWO PIP 2
BOT 5 IN 3, selects channel THREE PIP 3
BOT 6 GND GND
TOP 1 IN 4, selects channel FOUR PIP 4
TOP 2 Mute, turns OFF ALL channels PIP 5
TOP 3 Step, Steps through selected channels PIP 6
TOP 4 N/A PIP 7
TOP 5 N/A PIP 8
TOP 6 GND GND
STEP 6: LABEL SWITCHES
Write the source descriptions under each source switch, if desired.
STEP 7: SERIAL OPERATION
The supplied reversed modular cable and 9-pin female (S9) D-sub adapters may be
connected to the SS 4.1 Plus’s rear panel modular connector. Plug in the female DB-
9 D-sub adapter into your computer’s serial port. Plug the supplied wall transformer
into a source of 117 vac and the cable end of the transformer into the power recep-
tacle on the SS 4.1 Plus. The protocol is as follows: 2400, 4800, 9600, 38400, 8N1.
Flow control should be set to NONE, emulation to ANSI and the mode should be set
to DIRECT TO COMx (x = the available com port). The default is 9600, 8,N,1.
Commands
*uii Turn on input ii
EXAMPLE: *004 This string would turn on channel 4 on unit 0
*uMA Mute audio output (Turn Off Audio)
*uCA Set active channel for power up
*uCDEF Reset to factory defaults
*uCIIttt Set PIP minimum pulse length ttt: 000 – 255 => off to 2.55 seconds
*CLx Lock front panel. x = L (Lock) x = U (Unlock)
*uCFSx Set first step channel to x. x = 1 –> 4, 0 to disable
*uCSLx Set last step channel to x. x = 1 –> 4, 0 to disable
*uCSTtttt Set step interval in tenths: 0000 –> 99, Off to 99 seconds
*uDxx Delay xx seconds before processing the next command
*POLL Display unit ID in appropriate time slot
*uSL Send Audio Status: SuL1,x,x,x,x,x<cr><lf>
Note: x: 0 = Not Connected / x: 1 = Connected
*uSPi Send single PIP status i: SuP,i<cr><lf>
*0SS Send Silence Sensor Status
Response Example: S0S,0 = OK / S0S,1 = Alarm
*uSPA Send PIP status: SuP,A,x,x,x,x,x,x,x,x<cr><lf>
*uU Send unit info: name><firmware version><cr><lf>
*uY Display configuration
*uZx Echo character x to serial port (Used to debug command strings)