User manual

Table Of Contents
Section 4: Operation 4-27
Moseley SL9003Q 602-12016 Revision G
RX Clock
DATA Source:
RPT
CLK Source:
RPT
Clk Phase:
Normal
Inverted
FVers.
x.xx Firmware Version
Xvers.
xx IC firmware Version
4.4.13 Radio TX Status
Function Settings Summary
Freq A
948.0000 MHz Displays the transmitter output carrier frequency
XMTR
TRAFFIC
FORCED (default)
Status of transmitter:
ON in a hot standby mode
Forced ON
FWD
1.00 Watt (nominal) Output Power of TX
REV
0.07 Watt (nominal) Reverse (or reflected) power at antenna port
PA CUR
1.8 Amp (nominal) Power amplifier current consumption
TEMP
29.0 deg C (nominal) Power amplifier temperature
SYNTH
LOCK (nominal)
UNLOCK
Indicates phase lock of the 1
st
LO
AFC
2.4 VDC (nominal) 1
st
LO PLL AFC Voltage
LO
100% (nominal) 1
st
LO relative power level
XCTR
100% (nominal) Transmit module’s relative output power level