Section 4: Operation 4-19
Moseley SL9003Q 602-12016 Revision G
4.4.10 System: External I/O (NMS)
Function Settings Summary
Ext A/D
Readings:
#1- 0.00
#2- 0.00
#3- 0.00
#4- 0.00
Monitors analog inputs #1, #2, #3, and #4
dc levels.
(on pins 14, 13, 12, and 11, respectively of
Ext I/O high-density connector).
Ext Status
Readings:
#1- OFF
#2- OFF
#3- OFF
#4- OFF
Monitors digital inputs #1, #2, #3, and #4
logic levels.
(on pins 18, 17, 16, and 15, respectively of
Ext I/O high-density connector).
Ext Relays
RELAY CONTROLS
MAP FAULTS-RELAYS
-Map to Relays? OFF/ON
Relay Controls: Manually force relay
contacts closures for external relays
#1,#2, #3, and #4.
Map Faults-Relays: Maps fault logic to
contact closures for ext. relays #1-#4.
(on pin pairs 8-7, 6-5, 4-3, and 2-1 of Ext
I/O high-density connector).
Ext D/A
OUTPUT *RX SIG LVL
OUTPUT *TX FWD PWR
OUTPUT *Rev PWR
OUTPUT *BER
Controls monitoring output source of pin
10 on Ext I/O high-density connector.
Receiver: Received Signal Level 0-5 Vdc
Transmitter: Transmit Power 0-5 Vdc