User manual
Table Of Contents
- User Manual
- Starlink SL9003Q
- Digital Studio Transmitter Link
- WARRANTY
- SL9003Q Manual Dwg # 602-12016-01 R: G Revision Levels:
- Using This Manual - Overview
- Section 1 System Features and Specifications
- Section 2 Quick Start
- Section 3 Installation
- Section 4 Operation
- Section 5 Module Configuration
- Section 6 Customer Service
- Section 7 System Information
- Table of Contents
- List of Figures
- List of Tables
- 1 System Features and Specifications
- 2 Quick Start
- 3 Installation
- 4 Operation
- 7.1 Introduction
- 7.2 Front Panel Operation
- 4.3 Screen Menu Navigation and Structure
- 7.4 Screen Menu Summaries
- 4.4.1 Meter
- 4.4.2 System: Card View
- 4.4.3 System: Power Supply
- 4.4.4 System: Info
- 4.4.5 System: Basic Card Setup
- 4.4.6 Factory Calibration
- 4.4.7 SYSTEM: UNIT-WIDE PARAMS
- 4.4.8 System: Date/Time
- 4.4.9 System: Transfer
- 4.4.10 System: External I/O (NMS)
- 4.4.11 Alarms/Faults
- 4.4.12 Radio: Modem Status (QAM)
- 4.4.13 Radio TX Status
- 4.4.14 Radio RX Status
- 4.4.15 Radio TX Control
- 4.4.16 Radio RX Control
- 4.4.17 Radio Modem (QAM) Configure
- 4.4.18 Radio TX Configure
- 4.4.19 Radio RX Configure
- 4.4.20 Radio Modem/TX/RX Copy Function
- 4.5 Intelligent Multiplexer PC Interface Software
- 4.6 NMS/CPU PC Interface Software
- 5 Module Configuration
- 6 Customer Service
- 7 System Description
- 8 Appendices
- Appendix A: Path Evaluation Information
- Appendix B: Audio Considerations
- Appendix C: Glossary of Terms
- Appendix D: Microvolt – dBm – Watt Conversion (50 ohms)
- Appendix E: Spectral Emission Masks
- Appendix F: Redundant Backup with TP64 and TPT-2 Transfer Panels
- Appendix G: Optimizing Radio Performance For Hostile Environments
- Appendix H: FCC APPLICATIONS INFORMATION - FCC Form 601
- Starlink SL9003Q & Digital Composite - 950 MHz Band

3-4 Section 3: Installation
Moseley SL9003Q 602-12016 Revision G
The DC input is isolated from chassis ground and can be operated in a positive or
negative ground configuration. The power supply module is removable from the unit and
no high voltages are accessible.
DC P/S
DIG
ANA
PS IN
RFA
+5V
OUTPUT
VOLTAGES
DIG
+10V +12V
RFA ANA
+24V
+12V
VOLTAGE
24V/48V
+
GND
INPUT
GND
Nominal DC Inputs: 24 or 48 VDC
Operating Input Range: 20-72 VDC
Input Isolated from Chassis Ground
Typical Power Consumption:
Transmitter: 80 Watts
Receiver: 45 Watts
Status LED’s:
ANLG – Green Indicates +12V OK
DGTL - Green Indicates +5V OK
Figure 3-2 SL9003Q DC Power Supply
3.1.2.2. Fusing
For AC modules, the main input fuse is located on the switching power supply mounted
to the carrier PC board and the protective cage may be removed for access to the fuse.
For DC modules, all fusing is located on the carrier PC board.
Always replace any fuse with same type and rating. Other fuses are present on the
board, and are designed for output fail-safe protection of the system. All output fuse
values are printed on the back side of the PC board to aid in replacement.
NOTE:
If a fuse does blow in operation, investigate the possible cause of the failure prior
to replacing the fuse, as there is adequate built-in protection margin.