User manual

Table Of Contents
Section 3: Installation 3-3
Moseley SL9003Q 602-12016 Revision G
ANLG
110-240V, 47-63Hz
DGTL
AC P/S
DISCONNECT LINE CORD
PRIOR TO MODULE REMOVAL
CAUTION
AND RATING OF FUSE
REPLACE WITH SAME TYPE
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE,
!!
5V 10V 24V12V
Universal Input: 90-260 VAC, 47-63 Hz.
Typical Power Consumption:
Transmitter: 80 Watts
Receiver: 45 Watts
Status LED’s:
ANLG – Green Indicates +12V OK
DGTL - Green Indicates +5V OK
Figure 3-1 SL9003Q AC Power Supply
CAUTION
High voltage is present when the unit is plugged in.
To prevent electrical shock, unplug the power cable before servicing.
Power supply module should be serviced by qualified personnel only.
3.1.2.1. DC Input Option
An optional DC input power supply is available for the SL9003Q TX and RX, using a
high reliability, DC-DC converter capable of operation from an input range from 20 - 72
VDC. The power supply contains two DC-DC converters; the first regulates to 12V; the
second supplies 5V. An additional regulator supplies 10V for the PA (TX).